Justin Scace: Hello everyone, and welcome to EHS on Tap. Im your host, Justin Scace, senior editor of the EHS Daily Advisor and Safety Decisions magazine. Now, for those performing tasks in high risk industries, personal protective equipment or PPE is their last line of defense. Its important to be as informed as possible about all the PPE necessary to perform a job safely, but you may have some questions about the proper uses of flame resistant or FR garments within your PPE program. Fortunately, we have an expert on the podcast today that can provide you with the information that youre looking for.
On todays episode, were joined by Derek Sang, technical training manager for Bulwark FR. Derek has been involved in the flame-resistant clothing industry for over 20 years, taking on a variety of roles in the garment business from service to manufacturing to training. Over the course of his career, Derek has developed and conducted over 250 educational and informational seminars on FR technologies and the hazards of arc-flash and flash fire for a variety of organizations.
In his current role, Derek has developed over 40 hours of training curriculum for the Bulwark Institute, which focuses on non-commercial training for individuals and companies on thermal hazards, and how to properly design and implement an FR clothing program. Along with being a recognized subject matter expert, Derek is also a qualified safety sales professional, certified environmental health and safety professional and a certified safety health and environmental technician, making him the perfect expert to answer all of your burning FR questions. So thank you Derek for being here with us today on EHS on Tap.
Derek Sang: Justin, thank you for your kind introduction, sometimes Im not sure how to take that. It makes me feel old sometimes, but I certainly enjoy talking to you today.
Justin Scace: All right, well, so lets talk about FR or AR clothing meaning flame resistant or arc-rated. So, what protection does this clothing provide and what garments are out there?
Derek Sang: Well, first of all, lets clear up acronyms. I mean we do a great job and I have to remember that many of our end users here, FR and AR, may not be entirely clear on what that means. So, first and foremost, it depends on your hazard, what terminology youre going to want to focus on. All arc-rated clothing first and foremost has to be flame resistant, but not all flame-resistant clothing can be arc-rated. So, what does that mean to be flame resistant/arc-rated? Well, flame resistant means that its demonstrated through a variety of tests that it self-extinguishes, it puts itself out, it will not melt drip and add to the injury.
Arc-rated clothing or AR means that it has all those flame-resistant characteristics and it has gone through additional testing to protect you in an arc-flash hazard and its obtained thus an arc-rating. So, at the very basic, flame-resistant/arc-rated clothing eliminates clothing ignition, and mitigates burn injury by self-extinguishing.
Justin Scace: Okay. So what garments are out there? Were talking shirts, pants?
Derek Sang: Anything that you can find in the retail space. Everything that you can find in the non-FR space. For the most part you can find replicated in the flame-resistant/arc-rated clothing world. So, if youd like a particular style of jean, a particular style of outerwear jacket, et cetera, more than likely a flame-resistant/arc-rated clothing manufacturer replicated that.
Justin Scace: Okay. What about undergarments? Is it important for those to be flame resistant as well, just as much as outer layers?
Derek Sang: Yes and no. What I mean by that is first and foremost, everybody needs to be trained on what they can and cannot wear underneath their flame-resistant clothing, because it is important. The first thing we have to eliminate is any multiples, that includes all your blends, that includes your athletic performance gear that you wear in the gym that you may think, Hey, it keeps me cool, it helps me in hot environments when Im working out, Im just going to wear it under my flame-resistant/arc-rated clothing. No, dont do it, absolute no fly zone.
But all the standards allow for natural fibers to be worn underneath flame-resistant/arc-rated clothing, and that is fine. Why? Because natural fibers do not melt or drip and thus dont add to the injury. The caveat or the big asterix you need to see there is as long as that outer layer does not fail, meaning that theres not enough thermal energy in that arc-flash or that flash fire to break open my outer layer because if Im breaking [that] open then Im exposing whats underneath and thats usually two things. Thats either me and my birthday suit or thats my 100% lightweight cotton t-shirt a.k.a fuel, which is now exposed to thermal energy. So, I could technically be exposing fuel to energy by the outer layer breaking up.
So, if you look at good, better, best, wear your flame-resistant/arc-rated garment with just nothing underneath, better, look wear your flame-resistant/arc-rated garment with cotton or wool or silk underneath natural fibers, or best, have an additional layer of flame-resistant/arc-rated clothing underneath. There are lightweight base layers available today so that if that outer layer does fail in that thermal event, you have an additional layer protection. And at the very least, youve eliminated any chance of those lightweight cotton t-shirts igniting and causing injury that doesnt need to happen.
Justin Scace: Great. What trades or occupations should be most concerned with using FR clothing on the job?
Derek Sang: Well, if you think about it historically, first and foremost, the first to really adopt flame resistant clothing, and it was primarily coveralls at the time, was our refineries. Then from refineries we moved into general industry, electricians, that was our arc-flash hazards. Then utilities all came on board even though there was mixed adoption voluntarily throughout the late-90s and into the early-s. In , it became law that all our utilities had to wear flame-resistant/arc-rated clothing, and then most recently, you think of our oil and gas exploration, all the drilling that we hear about in our shale place, whether gas, its mandated that they have to wear clothing that has flame resistant properties.
One area today, if you were to ask me going Is there any place that were missing? I would say our combustible dust hazards is probably the biggest area thats often overlooked. We talk about combustible dust, which believe it or not, theres 30,000 businesses considered high risk for combustible dust by OSHA. OSHA doesnt have a regulation for combustible dust yet, but the new combustible dust NFPA 652 standard, and when I say new, we were out in , were now going into our first revision of that, requires a dust hazard analysis to get done.
If you have dust in a certain size particulate more than likely its going to be combustible. There is a vast array to dust that you wouldnt think about. Obviously, all our organics people can think of, wood, anything to do with vegetable matter, protein powders. Anything in a fine size is going to be combustible. But you get into your metals like bronze and iron and aluminum. One of the biggest combustible dust incidents we had was in China, thankfully not here in the U S, but hundreds were killed because of these massive fireballs that came out of combustible dust chain reaction, flash fires occurring in facilities.
So, what we find in the U S, is we do a great job down to the admin level. We look at our hierarchy of safety controls, we get down to admin and we forget about, even though its the least effective, it is the last line of defense and thats your PPE. If you have a combustible dust hazard, you should be implementing flame resistant clothing at some way, shape or form in those facilities. So, we have our historic core markets that we serve, that are discussed, and then probably one of the emerging markets that were looking at and keeping our fingers on the pulse off to see whats going, would be our combustible dust hazard.
Justin Scace: Absolutely. Moving on to the nitty gritty of whats in these garments, its like we hear a lot about the health dangers of some flame-retardant chemicals, things like a polybrominated diphenyl ethers or PBDEs. So, are there any similar concerns with FR garments, and are any chemicals used to treat the fibers and the clothing easily absorbed through the skin or are they otherwise hazardous?
Derek Sang: Great question, because there is a lot of misinformation in the marketplace. Theres use of terminology that are not entirely accurate today. For example, this question typically comes up two or three times a year. Therell be a broadcast news element, something will come through someones feed. Theyll be talking about cancer causing agents in fire retardants or flame retardants. Typically, most of those when you drill down, are in textiles that are used in other areas other than clothing.
Theyre used in equipment, theyre used to cover furniture, theyre used to slow down burn rates in your homes, in your walls, in construction, et cetera. Because theyre readily available, theyre relatively cheap and they are able to provide some basic flame resistance to these, otherwise elements that would be fuel. But when it comes to clothing, whats going on your back, first and foremost, people always focus on what the term treated versus inherent. Lets address that just for a second. Those terms in the 70s were very relevant. Why? Because you had cotton fiber a.k.a fuel that had a fire-retardant treatment put on it so that it would not burn.
Where do we see those garments used? Typically, in the steel industry, you had what was called inherent, which was your easily recognizable DuPont Nomex which dominated the refining environment and that was a molecular change of nylon into Nomex where it wont support combustion in the fiber itself. You actually changed the molecular makeup of a known product and by changing that it will not be consumed. Then you will not have fire, where cotton is fuel and you are treating it hence the term to impart flame resistant properties, so it will not be consumed and cause injury.
The problem is today, those terms are obsolete. Why? We have something called, for example, FR modacrylics, well FR modacrylics and non-FR modacrylics both exist, how can it be inherent? Because what happens is, when that acrylic is a soup before we extrude it into being a fiber, we add a ton of fire-retardant chemistry. Then we extrude it, so now the fiber has flame resistant properties in it.
Well, isnt it inherent? Well, no man had to make it. Well, was that Nomex fiber inherent? Well, technically no man had to, humans had to intervene and change the molecular formula. Well, what about that organic or that cellulosic a.k.a cotton, which we know as a fuel? Well, humans intervened and imparted fire-retardant chemistry into the fiber, so it now has flame resistant properties.
At the end of the day we engineer either at the fabric level, which is your cellulosics or what we call cotton rich for the most part. At the molecular level, like we talked about, our Nomexes, our Kermels, our Twarons and then the FR engineering occurs. Its permanent, it does not carry with it any of these PBDEs. Its never had the PBDEs as part of that fire-retardant chemistry.
So, when you talk about things to leak into skin, its a surface application. We can interact with the treatment itself. That is a misnomer when it comes to everything from quality manufacturers and quality sources here in North America, it does not occur. Both the CDC and NIOSH have recognized this, we did have a big study years ago on the antimony side, in our firefighting community for example, antimony is a known cancer-causing agent. It is a byproduct of FR modacrylics.
But what they were finding out is the exposure was not from their station wear, was not from their turnout gear, it was from them walking on the fire grounds post events and inhaling all the off-gassing from all these modern materials that are now in households. Think about how much antimony from the modacrylic fibers in your carpets, how much other agents are in the new building supplies that go into making a modern household. Theyve known that based on how quickly new homes are consumed versus the older building agents like we had in the 60s and 70s versus how were building today in the s.
So, thats a long winded answer to say that those discussions come up periodically when theyre in the construction industry, when youre talking about consumer products like electronics, when youre talking about new building materials, they are not in your flame-resistant/arc-rated clothing fabrics here in North America from quality supply chain partners.
Justin Scace: Okay, well thats definitely good to know. So how are these garments tested to verify their protective capabilities?
Derek Sang: Good question, because again, at the end of the day, we have to have a barometer, a measuring tool, because when we say flame-resistant/arc-rated, flame resistant and arc-rated to what?
Justin Scace: Right.
Derek Sang: Then we look at our standards, our people, our committees of like-minded folks who are experts in the industry. They come from manufacturing side, the retail side, the fiber fabric side. There are good solid cross section of people who get together and say, We have to have a bare minimum requirement of what we mean when we say flame-resistant/arc-rated properties. So, for our arc-flash hazard, we basically look at two primary ones. Thats ASTM . And within ASTM , theres ASTM , thats the actual test protocol to receive an arc-rating.
We actually take the three panels in the Faraday cage where we actually set off a controlled arc-flash in the Faraday cage. We expose it 21 different times to a certain fabric weight composition design all that, and it ends up coming out with arc-rating thats either going to be an ATPV, an arc thermal performance value or is an EBT, energy break open threshold. Theyre both the same, and whatever that occurs at, we run some really cool math and we come up with a 50% probability, the second-degree burn, thats a blister underneath or at that fabric if its broken open.
So, there we know, when we say that 8.6 calories of protection or 9.6 or 5.6, I now know how insulated and protective my garment is. I can then take that information, compare it to my arc-flash hazard assessment, and I know that, that gray box on the wall, according to my engineers, if that faults, itll produce four calories of energy. So, if I know I have four calories of energy coming out, what do you think my response is on my PPE? I want to have more. So if I have a four calorie box and five calories protection, Im going in the right area. I dont want to be in front of an eight calorie box though with six calories of protection.
So, we always want to have more arc-rating versus incident energy. Then on our flash fireside, its different hazard, both thermal, but this were talking about a short duration thermal exposure, typically three seconds or less, and we want to design garments out of fabrics that have been exposed to this environment. So NFPA is your standard there. Thats the standard that tells us as manufacturers how to build garments. Theres a number of tests in there, which fabrics have to pass.
The big one everybody thinks about is ASTM , thats your mannequin test. Thats the full mannequin dressed in a coverall. We set off eight burners on four torches, two burners per torch for two-calories-per-cm2 for a total of three seconds, so its six calorie exposure, and we have to have less than 50% body burn so that we can now start building garments out of that fabric.
So, within that range, youll have different fabrics, different weights that have a different body burn compositions so that you can start building garments. Now, the caveat there is you dont take the body burn graph as the sole predictor of your specification because its single layer, theres no pocket, theres no attribute, its not a commercially viable product. But that is a starting point for manufacturers. Once it passes that test, we can go through a number of other tests, then start building garments.
But what you know at the end of the day, whether its an arc-flash or a flash fire, if you have an arc-rating in the garment, its been tested to your hazard, and you know what it will insulate you to. In [NFPA] , you know its a minimum of less than 50% body burn, and then they start building garments towards them. So, bottom line is theyve been tested in the hazard that theyre supposed to be exposed to. Most of the garments are made out of fabrics today that are dual hazard. Youll see both an arc-rating and independently certified. Typically, UL has certified that it meets the requirements of NFPA .
So technically I can be on a refinery with a flash fire hazard as an electrician with an arc-flash hazard and I could be wearing the exact same garments and be protecting to both hazards.
Justin Scace: Oh, very cool. So, whats the usual shelf life for these FR garments? They sound, obviously, the testing youve described is pretty intense. I would assume, are they very durable?
Derek Sang: Really good question because this is as youre going through this evaluation process, first and foremost, it has to meet the standards, thats your bare minimum. Then you want to look at how durable is it? What are the manufacturers saying I can expect this performance to last? What you want to look for is guarantee for the life of the garment.
Now, two things when you say that, one; that sounds pretty salesy because it sounds somewhat ambiguous. What do you mean by that? Ill tell you that shortly. And then secondly, it does not correlate or have anything to do with the FR properties, assuming that its coming from a good quality manufacturer.
However, you rate that and you can think of all the manufacturers in the United States and North America here and youre probably going to be pretty good picking one of them, so Im not trying to be biased and point you to one. Im saying theres a number there, but you want to make sure it comes from quality manufacturers because life of the garment is what that real life is.
Meaning, if Im on a refinery, if Im working as a heavy-duty hydraulic mechanic, that garment may only last me eight months. Why? I just burn through clothes, the job that I do, the environment that Im in, how Im abrading that garment, what Im rubbing up against on a daily basis and I can just be hard on clothes.
I can be in the same refinery and I can be in operations, sitting in a controlled environment, air conditioned behind glass and all I do is push a green button and a red button alternating throughout the day. That coverall could last me seven years, if its in good wearable, usable condition the FR properties are guaranteed for life, and thats regardless of how that FR engineering was achieved.
Was it inherent, where we changed the molecular structure? Was it treated where we imparted FR chemistry into the fiber matrix? Or was it a hybrid where its an FR modacrylic with some aramid, with some para-aramid, with some Kevlar, with some lyocell, with some non-FR cotton for comfort however we achieve that FR engineering is irrelevant if its going to last for the life of the garment, and thats the guarantee that you want to see. Because then its durable, then you know that its going to perform day one, day and more importantly the day that you need it.
Justin Scace: Yeah, absolutely. Some jobs, theyre harder on these clothes than others. So, what if youre wearing this clothing while youre working with hazardous material? Like lets say youre removing asbestos or something like that. Are these garments washable or are they disposable? Like, whats the deal with that?
Derek Sang: Well, Im going to go answer that question backwards. First and foremost, there are disposable cover ups that you can get to protect that expensive flame-resistant/arc-rated clothing that youve got. Because on average today youre looking at $125 to $150 for a shirt and pants and you definitely dont want to be exposing it to something that could permanently damage it. So, there are disposable lightweight tie cam type products. The key there is if youre using anything as a disposable over the top of your flame-resistant/arc-rated clothing in a thermal hazard, make sure that disposable has thermal properties, that it will protect you, it will not ignite, melt drip and add to the injury.
Basically, you want it in an arc-flash or a flash fire to be consumed rapidly, so its not there. Then what youre wearing underneath, which is for that hazard, is going to do the bulk of the protection. So, you dont want that outer layer melting, dripping or igniting. So, you do want it to have some flame-resistant properties. Thats number one.
In the name of your question, or in the bulk of your question there, you talked about something about asbestos. Well, asbestos obviously is nasty, I dont want any of that getting on my garments. Can I be 100% sure that Im washing it out? Probably the question there would be, in all honesty, if I get 99.9% of it out, how do I document that?
So if I was asking that specific question from an end user, I would say, remove the hazard, eliminate the hazard, go through your hierarchy of safety controls and dont have to wear your expensive flame-resistant/arc-rated clothing while youre removing asbestos. Get it to where its de-energized or the hazard is not available. Then you can just get into the primary PPE for that hazard.
Youre going to get into something that in a thermal event would be meltable, but as designed for that hazard, youre going to have your breathing apparatus, your hood, youre getting into a barrier thats going to, that you just then dispose of through your proper safety practices, and the thermal is not a concern.
So, you wouldnt be wearing that expensive gear in there. You wouldnt be having to take it to that extra level of protection. So, if you do have to remove asbestos in an energized electrical environment or a flash fire threat environment, remove the hazard, and then you dont have to wear your expensive flame-resistant/arc-rated clothing.
Justin Scace: Definitely. So, what happens if the garment gets wet in the course of working? Does that affect its protective qualities at all?
Derek Sang: Good question, because theres two schools of thought here, in the lab and in the real world. We have seen in the lab when we get FR clothing wet, what it does is, arc-flash would flash steam that moisture, possibly transferring and theyve seen transfer into the calorimeter thats sitting behind that fabric where youre registering 1.2 calories-per-cm2. Thats the onset of a second-degree burn. So, when that happens, typically has been lower than the advertised insulative ATPV or arc-rating that we talked about.
So, lets say my arc-rating is 8.5, I saturate that garment, I do the test again and Im down now at six. So, Ive reduced my protection because the theory is that, that arc-flash is so intense, it flashes the moisture to steam, the steam transfers into my skin causing me to be injured. Thats in the laboratory.
Want more information on antistatic treatments textile? Feel free to contact us.
The tough thing is, we dont see that in the real world. We dont have any evidence of really anybody being in an arc-flash event when theyre soaking wet and being more injured than they should be under the protective PPE. So, its one of those tough things to really answer. Bottom line is were going to have to do a lot more work on it.
The other side of the equation that I always call to is, how wet is too wet? Were talking about sweat? Then, everybody sweats at a different rate. How are you going to manage and communicate that? If were in the rain, if were in the snow, if were in the sleet, theres additional PPE that you should be wearing. For now, your primary hazard is the environment. Don your arc-rated rain gear, don your ASTM rain gear for flash fire protection. Go get your rain gear on, go get that additional layer because now youre getting wet, youre getting rained on, youre going to potentially get cold, youre going to get uncomfortable and youre going to be at risk of causing or having an accident because youre fighting the environment.
So, good question. We have some lab results that were still kicking around. We have some real-world empirical evidence that we see and know when we have incidents. Then the other thing is, dont work wet. If youre starting to get rained on or you see rain coming, get down out of the bucket, get off the yard, either get back to your tool room and check out your appropriate and approved rain gear or get down out of the bucket, go in the cab and put your rain gear on and then get back to work. So, take your time and dont work wet if possible.
Justin Scace: Great. So, what about other wear and tear? You mentioned this a little bit before, if you get rips or holes in the clothing, is it okay to like patch those up yourself or do you need to get a new garment?
Derek Sang: This is one of those ones that turns into[groan]Im going to answer what the standards say and then Im going to tell you what Derek says.
This is your PPE, this is your last line of defense. Can you repair it? Yes. Heres the rules, like material. So, have an old shirt, old pant that you can use for patching, and use flame-resistant threads. So, most people have access to the Google box, get on Google, type in Nomex or aramid thread. Hopefully it pops up on Amazon somewhere, which I believe it does. If youre a Prime member, you can get it within two days and order yourself up some FR thread.
Now youre going to make little patches and youre going to sew them onto your clothing. It doesnt tell you how often you can do that. It doesnt tell you what size those rips and tears can be. So, whats the rule of thumb coming from Bulwarks technical people. If you make the okay sign with your thumb index finger, youve got three fingers standing up. Thats a tear of three inches. Thats our rule. If you reduce that thumb and index to the size of a nickel, that okay sign now tells you how big a hole and how long a rip you can repair.
Justin Scace: Okay.
Derek Sang: Now, Dereks. This is your PPE, this is your last line of defense. You do not allow your safety harness, your fall harnesses to be ripped, frayed, cut, tear, and you wear it properly. Take the same mentality with your flame-resistant/arc-rated clothing. I talk to guys all the time who wear their fall harness on a regular basis and have never fallen, but they would not be allowed to climb, they would not be allowed to climb, they will not be allowed to be in it, working at height, if there was a cut, a fray or a tear on any of that gear. Theyre not allowed to do it.
Why would you? Ive never been in a flash fire, Ive never been in an arc-flash, but Im going to allow my clothing to become threadbare, torn, patched up. We just take a completely different mindset when it comes to our last line of defense in clothing, yet if youre in a thermal event, thats the only thing that youve got working in your advantage to how youre going to come out of that, but youll jeopardize that by letting it get all torn up, secondary accelerants all over it, just gunked up and its not going to work as well as when you need it. Take the same mindset that you would with your fall harness and itll go a long way to wherever you need it to work, its going to work as best as it can.
Justin Scace: Yeah, thats really good point. My next question, I think I got an idea of the answer because we touched on it before, but can you wear other clothing on top of your FR clothing? Like if you have to wear hi-vis vest or other forms of PPE and maybe some of these garments arent flame resistant, can you wear those, or will that render the FR clothes ineffective?
Derek Sang: Justin, youve went from one of my pet peeves to my biggest pet peeve. Let me explain what I mean by that. If you are wearing arc-rated or flame-resistant clothing to the hazard, do not put anything on top of that, that has not been equally tested to work and perform in your hazard, because why? It will nullify all that investment, and all the performance requirements of that flame-resistant/arc-rated clothing that its on top of. So youve invested tens of thousands of dollars on your team over the year and you put a $25 hi-vis vest that says its FR on the packaging, and you put that on top, you can nullify that whole investment in literally the blink of an eye.
There are vests and rain wear out there today that have and are being marketed as flame resistant. Why? Theyre able to pass one test that allows them to market as FR. It is a grey area, a loophole, however you want to categorize it in what we do today. Now ANSI, because of the high visual requirements typically from vests and rain gear. ANSI 107- drilled down and said, Look, you cant claim to be flame resistant and ANSI unless you meet one of these six standards. ASTM , ASTM , ASTM , NFPA, Oh my gosh, its slipping me now, I should have it right on top of my head.
The bottom line is there are six categories that you cant, and if youre not in those six standards, you cant claim that youre flame resistant. The one that we see the most of today is on the label. Its ASTM and youll have the initials, SE meaning it self-extinguishes, that is meaningless in what we do in arc-flash and flash fire. In fact, its not a performance standard. All it said is it passed a vertical flame test. Its demonstrated that its self-extinguished, it meets a certain char length.
Well, think about it. If I hold plastic over flame, the plastic runs away from the flame, hence I dont ignite. Hence, I dont have a char length. That doesnt make you self-extinguishing by definition, it just says that you have kind of passed that test. Well, when you put that out there, people think, Oh well, its the same as being ASTM which is for rain gear and flash fire. Or its the same as ASTM which is getting an arc-rating in an arc-flash. It is not. The difference is, its about 25 bucks versus 75 bucks, which you should be paying, but youre trying to save $50 and that $50 save could jeopardize the tens of thousands of dollars that youre investing in your proper flame-resistant/arc-rated clothing.
So be very, very cautious. Be very cautious of people marketing that their vests meet NFPA 70E, and are Cat 2, thats impossible. The fact that people have it on their marketing brochures is shameful. Why? Right in NFPA 70E 130.7 it says, arc-rated shirt, pant coverall, you must have sleeves and you must be able to button it up, show me a vest with sleeves and show me that you can button it up. Then its called a shirt, not a vest.
Justin Scace: Right, right.
Derek Sang: So, when you see these companies marketing and using our terminology to convince you that theyve done the appropriate work, be very, very cautious. The easiest thing that I tell people, if your rain gear costs you a 100 bucks, you got the wrong rain gear. If your vest costs you 25 bucks, you got the wrong vests. It should be more like 400 to $500 for the proper rain gear thats going to protect your people in the hazard and closer to 75 to a 100 bucks for the vests that are going to protect your people if theres a hazard.
Justin Scace: Wow. Yeah, thats very important for our audience to know. Yeah, thank you for that advice. Now, Im going to shift gears here a little and we could talk a little bit about PPE compliance, thats always a big deal. So, I imagine that a common complaint that workers may have when theyre wearing their FR garments like, sleeves rolled down, tucked in, is it that theyre too hot? Are there any heat stress risks with this type of PPE and how can they be managed?
Derek Sang: Awesome, because if there is one thing categorically, if you say flame-resistant clothing, you may as well say too hot at the same time. Its that old psychology test, give me one word, when I say FR you say hot.
Justin Scace: Yep.
Derek Sang: Absolutely. So the answer is two-fold: First and foremost, when you say its hot, are you talking about actually something that is measurable, like heat stress or something thats entirely subjective, like comfort. And let me address comfort first, and here is why. Next time that you have a company meeting and youre sitting getting ready to address your team, take a look at your team.
Your team is sitting in a controlled environment, typically about, 68 to 72 degrees. As you look over your team of 20, 30, 40, 50, whatever the environment is, theyll be wearing t-shirts, short-sleeve polos, long sleeve polos, long sleeve t-shirts, a t-shirt and a hoodie, a hoodie, sweatshirt, sweatshirt and a t-shirt, long sleeve button down, short sleeve button down, and theyre all going to be comfortable in that environment or they would dress differently.
That being said, comfort is subjective. It has nothing to do with a measurable disease such as heat stress. So, how does flame-resistant/arc-rated clothing fit into a heat stress? The short answer is both OSHA and NIOSH have stated single layer, and this is important, flame-resistant/arc-rating clothing does not trap heat or restrict heat removal any more than regular non-FR clothing. Why is that? Because heat is shed primarily by evaporation of sweat. And what causes heat stress is the restriction of evaporation.
Because once you get into ambient air temperatures greater than 98.6 degrees, the three cooling methods that you have, excuse me, the four cooling methods that you have, youre only down to one and that is evaporation that is sweat. What restricts sweat is either physiological conditions like Im dehydrated or my medication or my physical fitness level. Then the other thing is if I put a barrier on there, yes, when we put a barrier, like we talked about tie cam, we talked about rain gear, we havent talked about arc-flash suits but donning an arc-flash suits has to be monitored.
That cant be an all-day environment. That is going to elevate our body temperature and we wont be able to cool off, and thats going to take us into heat stress conditions, and well march through rash, and well muck all the way through down to exhaustion where were calling 9-1-1. But the bottom line is that, when it comes to my basic all day, every day single layer, whether thats a shirt, pant or coverall, there is no correlation between the FR properties that are there versus if you had non FR properties.
More than likely any heat stress is going to be caused by something that is a physiological or to where weve introduced a barrier or multiple layers, heavy layers to where we are impeding that ability to evaporate.
Justin Scace: Okay. So, with any form of PPE ensuring that your workers are being compliant, training is vastly important. So, how can employers frame and present their training on this topic to ensure FR garment compliance and proper usage among their workers?
Derek Sang: Well, so first, shameless promotion here, my team of Bulwark certified trainers will come out and well take care of that OSHA .132 component to where you have to record and demonstrate and do all those things as far as donning and doffing your PPE and understanding what it cant do. And most important thing that we have to train our end users on is, what it can do. That all being said, having selected the proper flame-resistant/arc-rated garments for your hazard, thats the first step.
All your standards and all yourand importantly, your regulation says that you have to train people on how to correctly wear, and how directly that impacts what theyre going to do on a day-to-day basis. They have to know to tuck them in, roll them down, button them up, and thats how you implement your PPE on a daily basis. They have to be taught on what they can and cannot wear underneath their PPE.
Then as the employer, they get to document, Hey, that training was done, that training was 45 minutes. Everybody that attended, boom, boom, boom. Now, its documented. We can record that for [posterity]. So you can reuse it however you want to do it, but get what good subject matter experts, it should be a no-cost part of anybodys program and it should be relatively easy to get that regulatory requirement met.
Justin Scace: Great. Im sure that real world stories help drive home the importance of properly wearing FR clothing. Whether you tell them during training or maybe while on the job, during a toolbox talk or something like that. Now, do you have any story from the field about how FR garments have saved lives?
Derek Sang: Its probably the single most rewarding part of what we do Justin. On a regular basis we typically have either the end users themselves, their safety manager sending us pictures via . Weve got some of them up inwhat do you call those boxes? Those little boxes thatview boxes, I forgot the correct name for those. But we have those on display on our third floor of our facility. We see those on a timely manner.
Obviously, the garments have suffered the results of a violent short duration thermal event, whether thats an arc-flash or a flash fire, theyre damaged severely but the last line of that or the last line of that call always concludes with, And they were okay. Or They werent hurt as bad as they could have been. Its got some slight burns, but nowhere near what could have happened. Those are always great to share with our folks, especially when sometimes if youre on the front lines, if youre in customer service, if youre down on inside sales, if youre supporting this vast network, sometimes you forget that.
I tell my team all the time, Remember we do not make shirts, pants and coveralls. That sounds humorous when youre talking about the largest flame-resistant clothing manufacturer in the world. Thats not what we make, we make life saving pieces of equipment, and we want people to understand that. I hope you never have to use my shirt, pant or coverall for what we are building it for. Were building it to ultimately to save your life. I want you to go through your whole career saying, I never had to use your stuff for what you built it for.
That being said though, its so important that all those bells and whistles are built into that garment and are there when you need it. Because when you find out if youre going to cut some corners, if youre looking to buy or invest in inexpensive garments, there has to be some things cut out. Unfortunately, you dont know that until you need it. And thats the downside. Youre basically investing in the hope that you never have to use it for what its built for in the first place.
Justin Scace: Absolutely. So what does the future look like for FR garments? Are we looking at any new developments on the horizon?
Derek Sang: Arent we always? Arent we always? Our goal right now and where the market is trending is were looking to create true performance work wear for that occupational athlete, were looking to take all that technology, all that kinesiology, all that science of movement that were seeing in our performance world, in our performance fabrics, and were looking to get that into the flame-resistant/arc-rated market, and ultimately to fit the comfort equation, or the comfort objection back to your its too hot objection.
We want PPE thats going to aid our professionals and aid our safety people by driving compliance through comfort. Hows that going to look? Can we open up the weave? Think about it: garments are built to protect you against thermal energy. Thermal energy is going to find any window that it can get through. But, what if I had a fabric that stayed open and wide and allowed a lot of air permeability, but instantaneously fused shut as a barrier between you and that thermal event during when it happened.
Moisture wicking technology, thats not a finish, its actually built into and is a core characteristic of that fiber. So, it lifts moisture from your body rapidly moving it to the outside where it can evaporate, if youre dry, youre comfortable. But theres also other byproducts. When I start looking at thermal regulation, if I have big open spaces, those garments are easier to clean. If I move moisture rapidly, theyre easier to dry, so they become more economical to actually use.
You look at durability, utilizing fibers because why? Like I said earlier, a set is between $125 and $150. I dont want it lasting six months; I would like it to last about three years. So, increasing superior resistance to embrace and improve your ROI. But at the end of the day, we say all those things and none of them matter if first and foremost, I cant protect you. Protection comes first in what we do. Then, if I can be comfortable, great, if I can give you a great return on your investment, outstanding.
But first and foremost I have to protect. So, were looking at advancements in that FR engineering, looking at advancements in molecular fiber and fabric contents. Thats going to give you something that is supremely protective, ultimately a very, very comfortable wear. So, I increase compliance through comfort and at the end of the day you are comfortable making that payment on that lifesaving piece of equipment.
Justin Scace: Absolutely. Thats great. A lot of interesting stuff going on in this area of protective equipment. Thanks so much Derek for sitting down to chat with us today on EHS on Tap.
Derek Sang: Loved it Justin. I appreciate it and thank you for the time, and greatly thanks for the platform.
Justin Scace: Absolutely, youre very welcome. Thanks also to our listeners for tuning in. Now be sure to keep an eye out for new episodes of our podcast and keep reading the EHS Daily Advisor to stay on top of your safety and environmental compliance obligations. Get the latest and best practices and keep your finger on the pulse of all things related to the EHS industry. Until next time, this is Justin Scace for EHS on Tap.
When you conduct an average of 20 live trainings a year for over 500 people in seven different countries, most would consider you an FR expert. And thats exactly how many refer to Derek Sang. Derek has been involved with the flame-resistant (FR) clothing industry in a variety of roles from the service, manufacturing and garment sides of the business for over 20 years.The first 10 years of his career Derek worked directly with end users developing and implementing flame-resistant clothing programs specific to the customers hazards. Over the past 15 years, Derek has worked closely with fortune companies as they look to develop FR clothing programs, educating them on various fabrics and FR technologies as well as the dynamics of arc flash and flash fire hazards.
Over the course of his careers, Derek has developed and conducted over 250 educational and informational seminars on the hazards of arc flash and flash fire for a variety of companies, associations, and organizations including NSC, VPPPA, NJATC, NECA, and ASSP.
In his current position as a Technical Training Manager, Derek has developed over 40 hours of training curriculum for The Bulwark Institute. These training efforts cover all aspects of FR clothing and are delivered utilizing live class courses, online training, webinars, and in-person seminars. The Bulwark Institute focuses on noncommercial training for individuals and companies on the thermal hazards and how to properly design and implement an FR clothing program.
Along with being a recognized Subject Matter Expert (SME), Derek is also a Qualified Safety Sales Professional (QSSP), Certified Environmental, Health, Safety Professional (IASHEP), and Certified Safety Health and Environmental Technician (IASHEP).
EHS on Tap is an environmental, health, and safety podcast by BLRs EHS Daily Advisor. On each episode of EHS on Tap, our host will discuss emerging legal, regulatory, and policy issues with industry experts and the impacts to everyday safety and environmental professionals. EHS on Tap topics run the gamut of contemporary issues facing EHS managers and professionals today.
Download the podcasts on iTunes here, and also be sure to visit our SoundCloud page for a full listing of all of our episodes!
Using Flame Retardant Fabrics
Inherently FR Fabrics
IFR fabrics are made from fibers that intrinsically provide fire resistant properties; therefore, cleaning does not reduce the FR qualities. There are two types of IFR fabrics: natural and synthetic.
Wool and silk are fabrics with natural FR characteristics. Wool is generally considered the most flame retardant natural fiber, as it is difficult to ignite and may extinguish smaller flames on its own. Silk is also difficult to ignite, burns slowly, and may self-extinguish. Cotton and linen, on the other hand, burn quickly and easily.
IFR fabrics can also come from synthetic fibers that have been created with built-in flame resistance. Certain acrylic, polyester and nylon fabrics are constructed to be fire retardant, which results in them catching fire at much higher temperatures than natural fibers. And when those temperatures are reached, the fabrics typically melt rather than burn.
IFR fabrics can protect your family from fire without introducing chemically treated materials into your home. This would certainly be something to consider for seniors, people living alone, upstairs bedrooms, or children's rooms.
If you are looking for more details, kindly visit is nylon fire resistant.
74
0
0
Comments
All Comments (0)