Crossflow vs Counterflow Cooling Towers – A Technical Guide to ...

Crossflow vs Counterflow Cooling Towers – A Technical Guide to ...

Cooling towers are essential equipment in many industrial processes and air conditioning systems, providing an efficient way to release heat into the atmosphere. They are widely used in power plants, refineries, chemical processing plants, and other industrial facilities to maintain optimal temperature for equipment and processes. Among the different types of cooling towers, crossflow cooling towers and counterflow cooling towers are the most common designs. Depending on the application, operating environment, and performance requirements, each has its own characteristics.

If you are looking for more details, kindly visit Longzhuo.

This article will provide an in-depth comparison of crossflow cooling towers and counterflow cooling towers, analyzing them from the perspectives of design, operation, advantages and disadvantages, as well as best application scenarios.

1. Design and Operation

Crossflow Cooling Towers

In crossflow cooling towers, water flows in a horizontal direction. In a crossflow tower, air flows horizontally across the water flow direction, which intersects the downward water flow. Air enters the tower vertically, and the water flows downward across the fill. The fill helps increase the surface area for heat exchange.

  • Water flow: Horizontal
  • Air flow: Vertical (crosses with water flow direction)

Counterflow Cooling Towers

In counterflow cooling towers, water flows vertically downward, while air flows upward, opposite to the direction of the water flow. Water is sprayed from the top of the tower and passes through the fill, while air is drawn in from the bottom and flows upward, absorbing heat in the process.

  • Water flow: Vertical (downward)
  • Air flow: Vertical (upward)
  • (made by SPX)

2. Heat Exchange Efficiency

Both types of cooling towers aim to dissipate heat through heat exchange between air and water. However, due to the different directions of water and air flow, their heat exchange mechanisms differ.

  • Crossflow Cooling Towers: In this design, the contact time between water and air is shorter, so the heat exchange efficiency is relatively lower. The horizontal water flow may also lead to uneven water distribution, which can affect the overall heat exchange efficiency.
  • Counterflow Cooling Towers: The counterflow design allows for a more efficient heat exchange process. The upward flow of air and the downward flow of water result in a longer contact time between water and air, which improves heat exchange efficiency. The water distribution is more uniform, maximizing the effect of the fill.

Winner: Counterflow cooling towers generally have higher heat exchange efficiency due to better contact between air and water.

3. Space Requirements and Layout

The design of cooling towers directly impacts the amount of space required for installation.

  • Crossflow Cooling Towers: These towers are typically more compact and require less vertical space. With air entering from the side and water flowing horizontally, their design is wider and shorter, making them ideal for spaces with height restrictions.
  • Counterflow Cooling Towers: These towers are generally taller and more vertical in design, requiring more vertical space. Although they take up less floor space, they are better suited for areas with limited horizontal space but ample vertical space.

Winner: Crossflow cooling towers are more space-efficient when horizontal space is limited, while counterflow cooling towers are more suitable for areas with ample vertical space.

4. Maintenance and Accessibility

  • Crossflow Cooling Towers: Maintenance is usually more convenient for crossflow cooling towers, as the water distribution system and fill are typically located on the sides of the tower, making inspection, cleaning, and repairs easier. Additionally, the fan motor is usually located at the top of the tower, simplifying maintenance.
  • Counterflow Cooling Towers: Maintenance may be more challenging for counterflow cooling towers because the vertical design makes it harder to access the water distribution system, fill, and fans. Although the fan is usually located at the top, the vertical design may require more operational space for maintenance.

Winner: Crossflow cooling towers typically have an advantage in terms of maintenance due to easier accessibility.

5. Airflow

  • Counterflow Cooling Towers: Due to the longer contact time between air and water, counterflow towers require less air volume.
  • Crossflow Cooling Towers: Since the contact time between air and water is shorter, crossflow towers require more air volume to achieve heat exchange.

6. Fill Pack

Counterflow Tower Fill

In counterflow towers, the water flow direction is opposite to the airflow direction, so the fill must be designed to provide good heat exchange performance and anti-clogging properties. Common counterflow tower fill types include:

  • Film Fill: Offers a large surface area and excellent heat exchange performance. For example, MC75 film fill uses a cross-wavy design to provide efficient heat transfer, with a uniform fill spacing of 0.75 inches between sheets.
  • splash fill: Increases the contact between water and air by splashing, suitable for environments with lower heat exchange requirements.

Crossflow Tower Fill

In crossflow towers, the water flows horizontally, so the cooling tower fill must be designed to accommodate this unique air-water relationship. Common crossflow tower fill types include:

  • Film Fill: Similar to counterflow towers, crossflow towers also use film fill. For example, the wave height of crossflow tower film fill is typically 19mm, and the widths are available in multiple specifications, such as 610mm, 915mm, and mm.
  • Grid Fill: This fill has a larger porosity, making it suitable for situations where air resistance needs to be minimized.

7. Noise Level

  • Crossflow Cooling Towers: These towers tend to produce more noise due to the fan system and water distribution components. The horizontal water flow may create some turbulence, increasing noise generation.
  • Counterflow Cooling Towers: While counterflow towers also produce noise, the fan system is usually more efficient, and the vertical water flow helps reduce turbulence, making counterflow towers typically quieter than crossflow towers.

Winner: Counterflow cooling towers are generally quieter, making them more suitable for noise-sensitive environments.

8. Energy Efficiency

Energy efficiency is an important factor in the selection of cooling towers, especially for large-scale industrial applications.

  • Crossflow Cooling Towers: These towers typically require more fan power because of their lower heat exchange efficiency. At high load conditions, this can lead to higher energy consumption. The larger air volume required results in higher fan power consumption, and the pump head is higher as the distribution system is above the fan platform.
  • Counterflow Cooling Towers: Counterflow towers usually require less fan power because of their higher heat exchange efficiency. The lower fan power demand makes counterflow cooling towers more energy-efficient in operation. The air volume required is lower, resulting in lower fan power consumption, and the pump head is lower as the water inlet is located below the fan platform.

Winner: Counterflow cooling towers are typically more energy-efficient, especially in high-load applications.

9. Water Distribution and Performance

  • Crossflow Cooling Towers: In crossflow towers, the horizontal water flow may lead to uneven water distribution, which can affect the performance of the tower under certain conditions. However, modern water distribution systems and better designs can alleviate this issue.
  • Counterflow Cooling Towers: The vertical water flow in counterflow towers results in more uniform water distribution, providing more stable performance and ensuring efficient cooling under various load conditions.

Winner: Counterflow cooling towers provide more even water distribution and more stable performance.

10. Cost and Installation

  • Crossflow Cooling Towers: Crossflow towers are generally simpler in design and easier to install, which can make them more cost-effective in some cases. They are often more compact, requiring less space for installation.
  • Counterflow Cooling Towers: Counterflow towers have a more complex design and may require higher installation costs due to their vertical structure and increased height.

Winner: Crossflow cooling towers are generally less expensive to install.

Conclusion

Both crossflow and counterflow cooling towers offer unique benefits and are suitable for different applications. Counterflow cooling towers are generally more efficient in heat exchange, quieter, and more energy-efficient, making them ideal for large-scale industrial applications. On the other hand, crossflow cooling towers are typically simpler, more compact, and easier to maintain, making them a good choice for applications where space is limited or when lower initial costs are a priority. When choosing between the two, factors such as efficiency, space constraints, maintenance requirements, and noise considerations should be taken into account.

Different Types of Cooling Towers - Which Is Most Efficient?

July 12,

A cooling tower is a device that brings water and air into contact with each other, pulls heat from the water, then sprays cold water down through the tower. It provides large-scale air conditioning for a building. You’ll find cooling towers in many manufacturing facilities, health care settings, food processing organizations and power plants.

Multiple cooling tower styles use different heat transfer methods. In this second part of our guide to the different types of cooling towers, we’ll discuss heat transfer techniques, the differences between crossflow and counterflow cooling towers, ways to determine cooling tower efficiency and more.

Heat Transfer Techniques

A cooling tower is a heat exchanger that withdraws heat from the water through direct contact. Heat exchange occurs through the evaporation of a small portion of the water.

This evaporation reduces the temperature of the water circulating through the tower. The evaporated water and heat flow through the top of the tower as a fine mist. The cool water accumulates in a basin, then gets released back into the facility or plant for reuse.

There are four primary types of heat transfer methods.

1. Wet Cooling Towers

As the name implies, wet or open-circuit cooling towers use water to cool facilities. The following factors measure heat transfer in a wet cooling tower:

  • Increase of moisture in the air
  • Decrease in wet-bulb and process temperature
  • Coldness of water temperature

Wet cooling towers typically release tiny water droplets within the air stream. These aren’t hazardous, but you can still use special eliminators to reduce them. Open-circuit cooling towers are affordable, cost-effective, renewable and efficient, making them popular for various facilities.

2. Dry Cooling Towers

A dry cooling tower runs on an electric motor, which separates the working fluid from the ambient air to transfer heat. It doesn’t use any water, hence the name. There are two kinds of dry cooling towers.

  • Direct: A direct dry cooling tower condenses turbine exhaust steam through the tubes of an air-cooled condenser. Large piping at the turbine outlet accommodates low steam densities and reduces pressure drop through the route.
  • Indirect: An indirect dry cooling tower condenses turbine exhaust steam in a surface heat exchanger called a condenser. The exhaust steam’s heat gets transferred to the cold water pumped from the cooling tower’s air-cooled heat exchanger. The cooling water absorbs heat in the condenser and then gets pumped back to the heat exchanger.

3. Fluid Cooling or Closed-Circuit Towers

A fluid cooling tower mixes water with glycol, creating a fluid that travels through a coil. The fluid cools down as it circulates. While closed-circuit towers require more horsepower to achieve cooler temperatures, they offer high productivity and low downtime. They are ideal for surfaces that must be free of contamination.

4. Hybrid Cooling Towers

A hybrid cooling tower switches between dry and wet cooling operations to reduce water consumption. It balances water and energy savings to reduce its environmental impact. Air travels through the wet section before moving to the dry upper section.

The air from the dry and wet sections rises and mixes above the fan. This action results in little to no visible water vapor discharge.

Crossflow vs. Counterflow Cooling Towers

Induced draft cooling towers use mechanical systems like fans to move cool air. Below are two common types of induced draft cooling towers.

1. Crossflow

In a crossflow tooling tower, air travels horizontally through the system while hot water flows downward from distribution basins. Crossflow cooling towers use small pumps, making them cost-effective and straightforward to maintain.

Additionally, their non-pressurized spray enables more variable water flow. Essentially, variable flow or “turndown” is the effectiveness of cooling tower capacity for a given process flow.

However, crossflow towers tend to be less efficient and more prone to freezing than counterflow towers. Their fill can also become clogged with dirt and debris, especially in dusty, sandy and windy locations.

Related links:
The Ultimate Guide to Choosing 80G Radar Level  transmitter
Proper Installation of Rubber Oil Seals

Want more information on Counterflow Fill? Feel free to contact us.

2. Counterflow

In a counterflow cooling tower, air moves in the opposite direction of the falling water. In other words, air moves upward while water travels downward to cool the air.

Counterflow towers provide long-term energy-saving benefits. They tend to be more efficient because they’re more compact than their crossflow counterparts. Their spray distribution provides more freezing resistance. The spray volume’s large surface area also allows for more economical heat transfer.

However, counterflow cooling towers require larger pumps to push air, increasing energy use and utility bills. Additionally, they often experience less variable water flow than crossflow cooling towers.

Which Cooling Tower Is More Efficient?

To determine which type of cooling tower is more productive, it first helps to understand these two factors.

  1. Range: Cooling tower range is the difference between the temperature of the water entering and exiting the tower.
  2. Approach: Cooling tower approach is the difference between the cooling tower outlet’s cold water temperature and the ambient wet-bulb temperature.

Finding the range and approach can help determine the cooling tower’s efficiency. Fundamentally, cooling tower efficiency is the percentage of water temperature cooldown against the difference between hot water temperature and wet-bulb temperature. The formula is Cooling Tower Efficiency = Range / (Range + Approach) x 100.

Here are other strong indicators of cooling tower productivity.

1. Makeup Water Quality

Maximum cycles of concentration largely depend on local water quality. Therefore, knowing the makeup water compositions is critical to determine a cooling tower’s efficiency. Conducting a chemical analysis of the water can provide insight into makeup water quality. Mineral concentrations in makeup water can lead to scale formation, potentially affecting cooling tower capability.

The formula for makeup water quality is Makeup Water = Blowdown + Evaporation Loss + Drift Loss.

To address any scale buildup, a cooling tower water treatment specialist can flush the highly mineral-concentrated portion of the water down the drain, then replace it with fresh water. This process is cooling tower bleed-off or blowdown.

2. Cycles of Concentration

As mentioned, makeup water composition contributes to optimal cycles of concentration in cooling tower water. To find COC, you calculate the ratio of the blowdown water’s concentration of dissolved solids compared to makeup water. You can calculate COC using the following formulas.

  • Cooling Water Conductivity / Makeup Water Conductivity
  • Calcium Hardness in Cooling Water / Calcium Hardness in Makeup Water
  • Silica in Cooling Water / Silica in Makeup Water

The less makeup water in a cooling tower, the better. You might assume higher COC values indicate a more efficient cooling tower. However, a higher COC for the same amount of makeup water can increase the chance of heat transfer components scaling and fouling. The ideal COC balances makeup water requirements and heat transfer quality.

Which Cooling Tower Is Right for You?

Crossflow and counterflow cooling towers have their pros and cons. Ultimately, your site conditions and requirements will determine the appropriate cooling tower for your building.

So, what is the optimal cooling tower for your facility? Here are some essential considerations when deciding between a crossflow or counterflow cooling tower.

1. Variable Flow and Energy Efficiency

With federal and state energy efficiency requirements at play, a cooling tower with good turndown is ideal for increasing energy savings.

You can boost cooling tower capacity in a few ways, such as increasing the tower’s footprint, height or fan motor horsepower. Due to their water distribution techniques, crossflow towers generally have better variable flow than counterflow cooling towers.

2. Size

Cooling towers require different air volumes to exchange heat in process water, resulting in various sizes and configurations. You’ll need to consider your facility’s available space and the cooling tower size and height it can accommodate. A tall cooling tower may pose complications if your site has height restrictions.

Air and water interact vertically in a counterflow cooling tower. At cooling capacities of no more than 750 tons, a counterflow tower’s vertically stacked elements may require less physical space than a crossflow cooling tower. However, a counterflow cooling tower will likely occupy more space than a crossflow tower when capacities exceed 750 tons.

Depending on the application, a crossflow tower may require less space than a counterflow tower, even at heat loads below 750 tons. Primarily, this is because a crossflow tower has two air inlets, while a counterflow tower has four. Your facility’s height limitations and other space requirements will determine the importance of physical cooling tower size.

3. Maintenance and Water Treatment

Regular maintenance is essential to maintain cooling tower efficiency and extend its service life. Therefore, maintenance accessibility is another critical consideration when selecting a cooling tower. The ease of access to internal components often varies between crossflow and counterflow cooling towers.

In a crossflow tower, fill material surrounds the tower’s exterior portions. The tower has a tall, easily accessible plenum space, allowing you to inspect and service the motor, fan, drive system, drift eliminators and cold water basin. When working with a larger crossflow cooling tower, you can opt for a preinstalled ladder and platform to access the motor and drive.

On the other hand, a counterflow cooling tower’s overhead horizontal material creates a barrier between internal components, making maintenance access more challenging. While the operator may reach the cold water basin easily, accessing the motor, spray system, fan, eliminators and dry system is a different story because these components are above the horizontal fill.

4. Operating Weight

A crossflow tower has an inherently larger footprint, making its shipping and operating weight higher than a counterflow cooling tower. The crossflow tower’s steel casing, additional structural supports and piping for water distribution also contribute to its larger footprint.

With counterflow cooling towers, lighter-capacity cranes are usually necessary to lift individual vertically stacked components. You’ll need to weigh the potential logistical and crane savings against the need for additional picks per cell.

5. Noise

Cooling towers can generate high noise pollution levels, subjecting them to rigorous regulations. Organizations must abide by these laws to keep cooling tower noise at bay. Noise control is especially vital in settings like medical facilities, offices and residential buildings, making it challenging to manage applications that produce large loads.

Primary sources of cooling tower noise include fans, motors, airflow and falling water droplets hitting the collection basin. If excessive noise is a concern in your facility, consider these solutions.

  • Use premium cooling fans: Modern cooling fan designs typically include optimized blade profiles and inserts, reducing noise without compromising efficiency.
  • Install new drives or motors: Upgrading your cooling tower’s drive system or motor can help regulate the fan’s rotational speed, decrease sound and conserve energy during down periods or low temperatures.
  • Place noise-reducing mats on the basin water’s surface: These mats can help lessen the sound of water droplets falling into the basin.

Additionally, remember that counterflow cooling towers tend to be noisier than crossflow towers, as the water falls farther from the bottom of the fill into the collection basin.

6. Cold-Weather Operation

Cold-weather performance is critical, particularly when selecting a cooling tower for subfreezing conditions. Ice development poses a tremendous threat to cooling towers. Large ice blocks add significant weight to the tower’s structure and components, increasing the risk of collapse and damage.

Crossflow cooling towers tend to perform well in cold weather. Their gravity-fed distribution systems can disperse water evenly across the fill, even in low turndown situations. Uniform distribution helps prevent ice formation, scale buildup, water channeling, temperamental performance and tower damage. Using devices like dams or cups in the hot-water basin can help mitigate ice accumulation during cold-weather operations.

In low turndown circumstances, counterflow cooling towers have fewer nozzles and less head pressure, resulting in uneven water distribution across the fill. Inconsistent distribution can lead to issues like ice development, water channeling and scale formation.

Integrating louvers into your cooling tower can prevent splash-out that could turn to ice in subfreezing conditions. There is no external surface to stimulate ice formation.

Contact Chardon Laboratories for All Your Cooling Tower Water Treatment Needs

Regardless of the cooling tower you choose, proper maintenance is essential to optimize performance, reliability and longevity. Choose a water treatment specialist like Chardon Labs to assist you. Our ISO-certified service technicians provide various cooling tower services, including:

  • Inspecting and testing your current system.
  • Creating a customized chemical water treatment plan to address scaling, corrosion, bacterial growth and other issues.
  • Providing heat exchanger services.
  • Performing ongoing maintenance at a fixed annual cost.

We want to help you keep operating costs down and efficiency in full swing. That’s why we sell clean systems instead of chemicals. Rather than frequently spending money on chemicals to treat your water systems, let us handle everything instead.

If you want to learn more, please visit our website smc water tank.

53

0

Comments

0/2000

All Comments (0)

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name:(required)

Your Email:(required)

Subject:

Your Message:(required)

0/2000